Dose-response & drug-combination analysis

Curve fits with honest uncertainties.

Fit IC50/EC50 curves and score two-drug synergy in the browser. Real noise models instead of plain least squares, 95% confidence intervals on every parameter, and Bliss, Loewe, HSA and ZIP side by side.

No signup. Sample datasets included. Demo data is deleted after 24 hours.

synfit
synfit single-drug analysis: dose-response curve with 95% confidence band, replicate heatmap, IC50 and Hill coefficient with confidence intervals, residual plot, and a concentration prediction table
  • 95% CIs, always onOn IC50, Hill, top and bottom
  • Real noise modelsLognormal or heteroscedastic Gaussian
  • Click to excludeOutlier out, refit in a moment
  • 4 synergy referencesBliss · Loewe · HSA · ZIP

Single-drug dose-response

Every number comes with its uncertainty

A point estimate of IC50 without an interval invites over-confidence. synfit fits the Hill equation with a noise model that matches how assays actually scatter, and reports a confidence interval next to every parameter.

  • 4-parameter Hill, or 5-parameter with asymmetry
  • Click a point to exclude it, see the refit immediately
  • Inhibition (IC50) or activation (EC50)
  • Residual z-scores to check the fit, not just admire it
  • Tidy or wide CSV, format detected automatically
How the fit works →
synfit
New-analysis dialog: dose-response preview where points can be clicked to exclude, choice of 4- or 5-parameter Hill, error model (auto, lognormal, Gaussian with constant, Poisson-like or proportional variance) and parameter bounds

Drug-combination matrices

Four synergy references, one fit

Bliss, Loewe, HSA and ZIP answer slightly different questions, and they can disagree. synfit fits both drugs jointly and lays the four maps out side by side, so you see where they agree before you call a combination synergistic.

  • Joint two-drug fit with shared asymptotes
  • Deviation maps and the null (reference) prediction
  • Replicate heatmaps on a shared colour scale
  • Pan, zoom, hover; export any plot as PNG or SVG
Which synergy model should I use? →
synfit
Two-drug combination matrix with Bliss, HSA, Loewe and ZIP synergy heatmaps and the jointly fitted dose-response curves

Share & reuse

Turn a fitted curve into a shareable calculator

Fit a standard curve once and share a read-only link. Anyone with the link can back-infer concentrations from the same fitted model, with confidence intervals. No re-fitting, no spreadsheet drift, no signup for the viewer.

  • Inverse prediction table: response → concentration
  • Read-only share links you can revoke at any time
About inverse prediction →

Sharing an analysis, then predicting concentrations on the shared page.

While in academia, I've always bristled seeing wet-lab colleagues struggle with drug response fitting: the early-2000s UI, plots from even earlier times, the unintuitive treatment of uncertainties, if at all. I know of at least two concrete cases where these problems led them to invest months into a direction that should never have warranted such credence. So I built synfit.
Srdjan Sarikas, PhD · physicist, scientific software for R&D · LinkedIn

Open-source core

The maths is open. Check it.

The numerical library behind the app is synfit on PyPI, MIT-licensed for academic and commercial use. It ships synthetic datasets with known ground truth, so you can verify that a fit recovers what went in. Each analysis in the app records which library version produced it.

szarma/synfit on GitHub →
# the same fits, in your own pipeline
pip install synfit

Questions

How do I calculate an IC50 online with synfit?

Upload a CSV of concentrations and responses (one row per measurement, or a concentration × replicate table), check the preview, and run a fit. synfit fits a 4-parameter Hill (4PL) curve and reports IC50, the Hill coefficient and both asymptotes, each with a 95% confidence interval. CSV formats

Bliss, Loewe, HSA or ZIP: which synergy score should I use?

They rest on different null models of "no interaction", so the same data can look synergistic under one and additive under another. synfit computes all four from one joint fit and shows them side by side, so you can report the one your field expects and see whether the others agree. Bliss vs Loewe vs HSA vs ZIP

Why not plain least squares?

Assay noise usually grows with the signal. Least squares on raw responses lets the noisiest points dominate the fit and understates the uncertainty. synfit uses a lognormal or heteroscedastic Gaussian error model instead. Error models

Do I need an account?

No, not to try it. The demo gives you a temporary workspace with sample datasets; it and everything in it are deleted after 24 hours. Create an account to keep your datasets and analyses.

Where is my data stored?

On servers in Germany (Hetzner). synfit uses only strictly necessary cookies and no tracking. Details are in the privacy policy. synfit is in beta: please don't upload patient-identifiable data.

Can I run the fits myself, in Python?

Yes. pip install synfit gives you the same numerical core, MIT-licensed.

Bring a plate. See the error bars.

Start with the sample data, then try your own. Feedback on where synfit disagrees with your current tool is especially welcome.